®ISOMAX-TERRASOL Zero-Energy Building Technologies - Roof Structure with Solar Absorbers

The supply of solar energy has already been used in the most varied manner for many years, through the installation of liquid absorbers on rooftops.

The aesthetic appearance of a building is considerably affected by such systems. Local authority design guidelines and permit authorities thus justifiably frequently limit the use of such systems.

Due to the constant weather exposure of these systems, their lifetime is limited and the investment and maintenance costs weigh considerably on the economy of the building.

Schematic Diagram: Zero-Energy Building Technologies - Roof Structure with Solar Absorbers
Schematic Diagram: Zero-Energy Building Technologies - Roof Structure with Solar Absorbers
Zero-Energy Building Technologies - Roof Structure with Solar Absorbers
Zero-Energy Building Technologies - Roof Structure with Solar Absorbers

The "® ISOMAX construction technology" successfully fulfils the following important targets due to its own absorbing design:

  • invisible and thus does not affect appearance
  • greatest possible expansion of the size of the system
  • differentiated temperature and energy yield from segments of absorber
  • maximum efficiency in energy gain
  • protects the system components from weather exposure
  • minimizes investment and maintenance costs

The entire ® ISOMAX absorption technology is installed below the roof, but above the insulation layer of the roof structure.The architectural design of the building thus remains absolutely unaffected.

The size of the system can be determined and created as desired, limited only by the area of the roof.

The layout of the system, protected from weather exposure, guarantees optimum energetic efficiency. The air temperatures between the roofing and insulation layer only change slightly with frequent changes in outside temperature. The remaining air energy reserves can be additionally used without draft losses.

Energetic and thus absorbable energy gain occurs under the roof even with winter sun-shine. Even small levels of energy gain from the separate thermo-controlled absorber segments are stored in one of the four respectively available storage circuits.

Energy transfer and thus energy loss does not occur in the roof as the roof structure, in connection with the insulation of the building shell, has a thermal insulation layer of 30 cm.
Even if rooftop absorbing structures can have a higher effective use/m² in special situations, their useable surface (in m²) per building remains limited for the reasons previously mentioned.
The rate of solar energy gain per building is thus also reduced to values which are too low.
The large surface of the absorber systems used in ® ISOMAX construction technology favors the yearly energy gain rates besides other operating results, due to the fact that, in contrast with other systems, the entire absorbing area is activated even during the shortest spells of sunshine. The result is optimum energy gain.
The simple and materially-tested design and installation reduces the investment and maintenance costs of this system to a minimum.

As a comparison, a reduction in costs of 95 %/ m² of collecting surface can be achieved. To calculate the defined energy gain for the air-conditioning of a building and the coverage of the fixed heating requirement, the standard planning preparations for determining efficiency are always valid.

A building location must be chosen carefully and the values of the sunshine zones with hours of sunshine, intensity of rays and possible thermal loss due to convection and radiant heat are to be determined.

Bauarbeiter sind keine Uhrmacher

Liebe ISOMAX – Partner und Freunde,

Bauarbeiter sind keine Uhrmacher !

Es ist jedoch dringendst erforderlich, eine Mindestsorgfalt und Präzision zum perfekten Isomax-Passivgebäude anzuwenden.

Anlässlich meiner diversen internationalen Baustellen-Besuche, muss ich doch manches Mal „kleine Versäumnisse“ mit später schwerwiegenden großen Problemen feststellen.
Häufig – Gott sei Dank – nicht immer, werden nach dem Setzen des Dachstuhles auf das gedämmte Außen-Mauerwerk, die  „Styropor-Passstücke“ der nach oben fehlenden Dämmung zum Dachanschluss der Sparren und der Dachdämmung, äußerst unsachgemäß, mit extrem großen „Toleranzen“, eingesetzt.
Dann wird bekanntlicherweise die Schaumpistole zum Vertuschen fehlender sauberer Facharbeit genutzt und alles hat den Anschein solider Facharbeit !
Nach dem späteren Entfernen des überschüssigen Schaumes, verbleibt in den meisten Fällen lediglich eine 1-2mm Verbindung des „Passstückes“ zum Sparren bzw. der Dachdämmung.
Warum also 7-10 cm Dämmung, wenn lediglich 1-2mm Dämmung linear um das gesamte Gebäude per „Facharbeit „  ausgeführt wurden ?
Die eindringende Kälte/Wärme trifft von außen durch das nicht präzise Styropor-Passstück auf das gut gedämmte Isomax-Mauerwerk und auf die innenliegende ebenso fehlerhafte Dämmung.
Die  ROT-markierten  „Keile“ der Skizze zeigen deutlich  die  sträflich verursachten enormen Wärmebrücken.
Nach dem späteren Aufbringen des Außenputzes, dem Verlegen der teuren Badezimmerfliesen, den neuen und schönen Tapeten, wird der „selbsternannte Fachmann“, sein „Wissen“ verkünden:
„Seht, Isomax hält nicht was es verspricht“!
Nur eine Wärmebildkamera kann das Phänomen des hohen Energieverlustes aufzeigen.
Die „Reparatur“ wird extrem teuer und zusätzlich sehr viel Ärger verursachen.
Also bitte, liebe Freunde:
Glauben ist gut, Baustellenkontrolle ist besser und schafft zufriedene Kunden!

Meine zusätzliche Empfehlung:

weltweit habe ich tausende von Isomax / Isorast Gebäuden errichtet. Ich „entsorgte“ alle Styropor-Abfälle, in dem ich diese zerkleinerte und die Hohlräume am Dach damit von oben verfüllte.
Ich wünsche euch allen eine friedliche Weihnacht und ein erfolgreiches
ISOMAX – NEUJAHR  2010

Dipl.-Ing., Phys. Edmond D. Krecké

Sorgfalt beim Übergang der Mauer zum Dach